50
Adjust the brake
General
Setting the brake:
D200 device
1 2
3
CAUTION! Risk of injury and material damage from the welding current and ac-
cidental ignition of an arc. Before starting work, disconnect the ground earth con-
nection between the welding system and the workpiece.
CAUTION! Risk of injury and damage from wire electrode emerging. While work-
ing:
- hold the welding torch with the point directed away from the face and body
- wear suitable protective goggles
- do not point the welding torch at people
- make sure that the wire electrode does not touch any conductive or earthed
parts, such as the housing, etc.
NOTE! After releasing the torch trigger the wirespool must stop unreeling. If it
continues unreeling, readjust the brake.
1
4
5
STOP
6
7
3
1
2
1
2
2
4
STOP
OK
3
1
3