EasyManua.ls Logo

Fronius WF 25i Case D200 - Technical Specifications

Fronius WF 25i Case D200
76 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
65
EN
Technical data
WF 25i Case D200
WF 25i Case D300
Supply voltage 24 V DC / 60 V DC
Nominal current 0.5 A / 1.2 A
Welding current at 10 min/40 °C (104 °F) 40% D.C.* 60 % D.C.* 100 %
D.C.*
500 A 450 A 360 A
Maximum shielding gas pressure 7 bar
101.53 psi
Coolant Original Fronius
Maximum coolant pressure 5 bar
72.53 psi
Wire feed speed 1 - 25 m/min
39.37 - 984.25 ipm
Wire drive 4-roller drive
Wire diameter 0.8 - 1.6 mm
0.03 - 0.06 in.
Wirespool diameter max. 200 mm
max. 7.87 in.
Wirespool weight max. 5 kg
max. 11.02 Ib.
Degree of protection IP 23
Mark of conformity S, CE
Dimensions l x w x h 507 x 200 x 320 mm
19.96 x 7.87 x 12.6 in.
Weight 9.5 kg
20.94 Ib.
*) D.C. = Duty cycle
Supply voltage 24 V DC / 60 V DC
Nominal current 0.5 A / 1.2 A
Welding current at 10 min/40 °C (104 °F) 40% D.C.* 60 % D.C.* 100 %
D.C.*
500 A 450 A 360 A
Maximum shielding gas pressure 7 bar
101.53 psi
Coolant Original Fronius
Maximum coolant pressure 5 bar
72.53 psi
Wire feed speed 1 - 25 m/min
39.37 - 984.25 ipm
Wire drive 4-roller drive
Wire diameter 0.8 - 1.6 mm
0.03 - 0.06 in.
Wirespool diameter max. 300 mm
max. 11.81 in.

Table of Contents