LOV
™
Technical Reference
22
Problem Probable Causes Corrective Action
M2007 display is in wrong
temperature scale (Fahrenheit
or Celsius).
Incorrect display option programmed.
M2007 computers may be pro-
grammed to display in either Fahr-
enheit or Celsius. Press and hold
and simultaneously until code
appears. Enter
1658. The com-
puter displays
OFF. This toggles
the temperature from F° to C° or
vice versa. Turn the computer on
to check temperature and see the
temperature scale. If the desired
scale is not displayed, repeat.
M2007 display shows
hot
hi 1.
Frypot temperature is more than 410ºF
(210ºC) or, in CE countries, 395ºF
(202ºC).
This in an indication of a malfunc-
tion in the temperature control
circuitry, including a failure of the
high-limit thermostat.
M2007 display shows
HI-
LIMIT.
Computer in high-limit test mode.
This is displayed only during a
test of the high-limit circuit and
indicates that the high-limit has
opened properly.
M2007 display shows
low
temp.
Frypot temperature is between 180°F
(82°C) and 315°F (157°C).
This display is normal when the
fryer is fi rst turned on while in the
melt cycle mode. To bypass the
melt cycle press and hold the #2
product button under the LCD
display until a chirp is heard. The
alarm will chirp and the computer
displays
EXIT MELT alternating
with
YES NO. Press the #1
YES
button to exit melt.
The fryer may temporarily show
low temp when a large batch of
product is added to the frypot.
However, if low temp is shown
constantly, the fryer may not be
heating.
M2007 display shows
PROBE FAILURE.
Problem with the temperature measur-
ing circuitry including the probe.
This indicates a problem within the
temperature measuring circuitry.
Check probe resistance. If faulty,
replace probe.
M2007 display shows
PROBE FAILURE
with
alarm sounding.
Damaged computer wiring harness or
connector.
Swap the computer wiring harness
with one known to be good. If
problem is connected, replace
harness.
M2007 display shows
IGNITION FAILURE.
Open drain valve, failed computer,
failed interface board, open high-limit
thermostat.
This indicates that the fryer is not
heating. It is displayed if the fryer
loses its ability to heat oil. It is also
displayed when the oil temperature
is above 450°F (232°C) and the
high-limit thermostat has opened,
halting the heating of the oil.
Verify that the drain valves are fully
closed.