Color Management Menu
ACES Proxy v1.0.0
Largely deprecated and not commonly used, but kept in rmware for select applications and testing. Provides selection of
R709 ODT or DCI P3 ODT for application when monitor is receiving an ACES Proxy signal (v.1.0.0). Please note, ACES
Proxy workows are fairly rare and should not be confused with standard ACES workows. For typical ACES workows
transforms will be done upstream of the monitor and the monitor simply needs to have it’s color space and gamma set to
match the upstream ODT being used. For example, if the upstream ODT is Rec709/2.4 then the monitor should be set to
Color Space: Rec709, Gamma: 2.4 from the Color Management menu. The ACES Proxy toggle is NOT used in such use
cases. This point bears repeating: unless you are specically sending an ACES Proxy signal to the monitor do NOT use this
feature.
SDI Black Level
Use this toggle to set the monitor’s black level for Video (Legal) range or Data (Full) range. Please ensure that your video
signal is setup to match this setting. When set to Video, bit level 16/64 (8 or 10 bit) will be the blackest level on screen. Levels
below 16/64 will not be distinguishable from level 16/64. When set to Data, bit level 0/4 will be the blackest level on screen
and any levels above this will be distinguishable as brighter levels. Once set to match your video signal path the brightness
knob can be used to make subtle adjustments to optimize lowlevel response for your particular viewing environment.
Video Clipping
Setting Video Clipping to On will clip all levels exceeding legal broadcast limits. With Video Clipping on you can see how
source content will look if clipped within legal broadcast limits. Setting Video Clipping to Off will show you the full range of
levels onscreen, this is the recommended operating mode.
Custom Gamma
Allows a custom 1D LUT for EOTF / Gamma to be activated. Contact FSI support for assistance with generating and loading
custom EOTF LUTs. Up to 3 custom user LUTs for EOTF can be uploaded to
SDI Hue Adjustment
This option allows you to activate the HUE (PHASE) adjustment knob while monitoring in SDI. In analog monitoring modes
(i.e. Composite Video) the HUE (PHASE) adjustment will always be active. Technically speaking Serial Digital being both a
Digital and YCbCr or RGB video format should not require a HUE (PHASE) adjustment, but should you wish to have such
an adjustment in SDI you should set this option to On.
Factory AWB
Used at the factory level or with the CA310 DCAA kit. Not used for 3D LUT based calibration with third party calibration
software.
Reset Factory Alignment
The password protected Reset Factory Alignment option is for use by FSI and/or authorized FSI service centers only. This
option does not reset your monitor to factory default mode, but rather deletes factory calibration data. To reset to factory
default mode go to the System Menu, select Load Prole, select Default, and then conrm by pressing enter.