8-6
Enable terminals and peripheral circuit, and internal circuit configuration
Figure 8.5 FRENIC-Lift Inverters compliant with
EN81-20 5.9.2.5.4 d) or EN81-20 5.9.3.4.2 d)
Safety circuit breakers
complying with more than EN ISO 13849-1 Cat.3
External safety switch complying with
more than EN ISO 13849
-1
Cat.3, PL-e
EN62061/EN61508 SIL3
M
3~
Conventional Inverter
Power
supply
Reset
“Enable” input
Emergency Stop
FRENIC-Lift(LM2) Inverter
[L1/R]
[L2/S]
[L3/T]
[PLC]
[EN1]
[EN2]
[Y*]
[CMY]
Reset
Emergency
Stop
6
“Enable
input
Output IGBTs
Safety
Related
Circuit
[U]
[V]
[W]
External safety switch
with higher compliance than
EN ISO 13849-1 Cat.3, PL-e
EN62061/EN61508 SIL3
Power
supply
M
3~
DECF
Note) Y* terminal set to DECF function..
Figure 8.4 Conventional Inverters compliant with
EN81-20 5.9.2.5.4 d) or EN81-20 5.9.3.4.2 d)