EasyManua.ls Logo

Fuji Xerox ApeosPort-IV C4430

Fuji Xerox ApeosPort-IV C4430
393 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Ground Fault Interrupter
47
Product Overview
2
Ground Fault Interrupter
The machine is provided with a ground fault interrupter.
In the event of a current leakage, the ground fault interrupter will automatically cut off
the power circuit to prevent any leakage of fire from occurring.
Check that the ground fault interrupter works properly at least once a month.
Be sure ground fault interrupter may be disabled, causing a risk of electric shock.
If you have any problems with the ground fault interrupter, contact our Customer
Support Center.
The following describes how to check the ground fault interrupter.
1 Press the power switch to the [ ] position to
switch the power off.
2 Make sure that the touch screen is blank and the <Energy Saver> button does not
light up.
3 Press the main power switch to the [ ]
position to switch the main power off.
4 Press the <RESET> button. The button will
be depressed even after the pushing force is
released.
5 Press the <TEST> button lightly with a sharp
edge such as a pen tip. The depressed
<RESET> button will stick out again.
This is the end of the check procedure.
6 Press the <RESET> button back to the depressed position.
Ground Fault Interrupter
Reset Button
Test Button