EasyManuals Logo

Fujitsu AOYG18LBCB User Manual

Fujitsu AOYG18LBCB
59 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #39 background imageLoading...
Page #39 background image
12-2. Cassette grille
Exterior Part name Model name Summary
Cassette grille UTG-UFYD-W
The form of grille discharges wind
away from the ceiling making it
difficult to leave dirt marks.
12-3. Others
Exterior Part name Model name Summary
External
connect kit
UTY-XWZX
Use to connect with various
peripheral devices and air conditioner
PCB.
Air outlet
shutter plate
UTR-YDZB
Installed at the air outlet when 3-
directions mode is performed.
Fresh-air intake
kit
UTZ-VXAA
By attaching Fresh-air intake kit to
the indoor unit, it can be taken in
fresh air of up to 10% of “high” air
volume of the indoor unit.
Insulation
kit
Insulation for
high humidity
UTZ-KXGC
Install when the under-roof condition
is expected to be the humidity of over
80% and the temperature of over
30 °C.
- 35 -
CASSETTE TYPE
AUYG18-24LVL

Other manuals for Fujitsu AOYG18LBCB

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Fujitsu AOYG18LBCB and is the answer not in the manual?

Fujitsu AOYG18LBCB Specifications

General IconGeneral
TypeAir conditioner outdoor unit
IonizerNo
Multi-split-
Product colorWhite
Gas hose diameter12.7 mm
Hose length (max)25 m
Hose length (min)15 m
Remotely operatedYes
Drain hose diameter32 mm
Liquid hose diameter6.35 mm
Refrigerating mediumR410A
Dehumidifying capacity2 l/h
Air conditioner functionsCooling, Dehumidifying, Heating
Cooling capacity in watts (nominal)5200 W
Cooling energy efficiency (EER, W/W)3.21
Heating energy efficiency (COP, W/W)3.61
Operating temperature (cooling) (T-T)-10 - 46 °C
Operating temperature (heating) (T-T)-15 - 24 °C
Seasonal efficiency rating (cooling) (SEER)6.1
Seasonal efficiency rating (heating) (SCOP)4.2
Heating capacity in watts (nominal) (Warmer heating season)- W
Heating capacity in watts (nominal) (Average heating season)6000 W
Seasonal efficiency rating (heating) (SCOP) (Average heating season)4
AC input voltage230 V
Current (cooling)11.5 A
Current (heating)13.5 A
AC input frequency50 Hz
Design load (cooling)298 kW
Energy efficiency class (cooling)A++
Hourly energy consumption (cooling)- kWh
Design load (heating) (Warmer heating season)- kW
Design load (heating) (Average heating season)1819 kW
Energy efficiency class (heating) (Warmer heating season)A+
Outdoor unit depth290 mm
Outdoor unit width799 mm
Outdoor unit height632 mm
Outdoor unit weight36000 g
Outdoor units quantity1
Outdoor unit noise level50 dB
Cooling airflow (outdoor unit)2380 m³/h
Indoor unit noise level (high speed)- dB