11. Safety devices
Type of
protection
Protection form
Model
AOYG18LBCB AOYG24LBCB
Circuit protection Current fuse (Main PCB)
250 V, 25 A 250 V, 25 A
250 V, 5 A 250 V, 5 A
250 V, 3.15 A 250 V, 3.15 A
Fan motor
protection
Terminal protection
program
Activate
125±10 °C
Fan motor stop
125±10 °C
Fan motor stop
Reset
120±10 °C
Fan motor restart
120±10 °C
Fan motor restart
Compressor
protection
Terminal protection
program
(Discharge temp.)
Activate
115 °C
Compressor stop
110 °C
Compressor stop
Reset
After 3 minutes
Compressor restart
After 3 minutes
Compressor restart
DESIGN & TECHNICAL MANUAL
- 54 -
OUTDOOR UNIT
AOYG18-24LBCB