- (02 - 02) -
OUTDOOR UNIT
AOGA18-25FBTAH
OUTDOOR UNIT
AOGA18-25FBTAH
DIMENSIONS2.
MODEL
: AOGA18FBTAH
(Unit : mm)
INSTALLATION PLACE
(Unit : mm)
350
830
650
12
101
154
343
320
58
603
Air flow
Bottom
90
Top view
Front view
Side view
Bottom view
* If the space is larger than stated, the condition will be the same as those without any obstacles.
Height above the oor level should be 50 mm or more.
When there are obstacles at the
back and front sides.
When there are obstacles at the
back, side(s), and top.
When there are obstacles at the
back side with the installation of
more than one unit.
600
or more
300
or more
300
or more
300
or more
*600-1000
300
or more
300
or more
300
or more
300
or more
(Service space)