Model: ARTH54KMTAP
AFR
m
3
/h
2,160
Indoor temperature
°CDB 18 21 23 25 27 29 32
°CWB 12 15 16 18 19 21 23
Outdoor temperature
°CDB
TC SHC IP TC SHC IP TC SHC IP TC SHC IP TC SHC IP TC SHC IP TC SHC IP
kW kW kW kW kW kW kW
-10 9.22 7.10 1.83 10.00 7.46 1.87 10.53 7.69 1.91 11.04 8.02 1.93 11.57 8.34 1.96 12.05 8.48 1.96 12.77 8.72 1.96
0 9.38 7.23 1.90 10.17 7.59 1.94 10.70 7.84 1.98 11.24 8.17 2.00 11.76 8.49 2.03 12.26 8.65 2.03 12.99 8.89 2.03
5 9.21 7.14 1.95 9.99 7.50 1.99 10.51 7.74 2.02 11.03 8.06 2.05 11.56 8.39 2.08 12.03 8.54 2.08 12.76 8.77 2.08
10 9.05 7.04 1.99 9.81 7.40 2.04 10.32 7.64 2.07 10.83 7.95 2.10 11.35 8.27 2.12 11.82 8.43 2.12 12.53 8.65 2.12
15 8.89 6.93 2.06 9.65 7.28 2.12 10.15 7.52 2.14 10.65 7.83 2.17 11.15 8.15 2.20 11.62 8.29 2.20 12.32 8.52 2.20
20 11.87 8.90 3.67 12.88 9.34 3.75 13.55 9.64 3.80 14.22 10.04 3.86 14.89 10.44 3.91 15.51 10.63 3.91 16.45 10.92 3.91
25 11.37 8.66 3.79 12.33 9.11 3.88 12.98 9.40 3.93 13.62 9.79 3.99 14.27 10.18 4.04 14.86 10.37 4.04 15.75 10.65 4.04
30 10.86 8.44 3.91 11.79 8.88 4.00 12.40 9.15 4.06 13.02 9.53 4.12 13.63 9.91 4.18 14.20 10.10 4.18 15.05 10.37 4.18
35 10.36 8.22 4.04 11.24 8.63 4.13 11.83 8.91 4.19 12.41 9.29 4.25 13.00 9.66 4.31 13.55 9.83 4.31 14.35 10.09 4.31
40 8.83 7.52 3.92 9.58 7.90 4.00 10.08 8.16 4.07 10.58 8.49 4.13 11.09 8.83 4.18 11.55 9.00 4.18 12.24 9.24 4.18
46 7.53 7.19 3.59 8.18 7.55 3.67 8.61 7.79 3.73 9.02 8.12 3.77 9.45 8.44 3.83 9.84 8.60 3.83 10.44 8.83 3.83
50 5.92 5.92 2.69 6.22 6.22 2.75 6.42 6.42 2.79 6.69 6.69 2.83 6.95 6.95 2.87 7.24 7.08 2.87 7.68 7.27 2.87
- 11 -
4-1. Cooling capacity
4. Capacity table
DUCT TYPE
ARTH30-54KMTAP
DUCT TYPE
ARTH30-54KMTAP