4-2. Heating capacity
NOTE: Values mentioned in the table are calculated based on the maximum capacity.
¢
Model: ARTH30KMTAP
AFR
m
3
/h
1,950
Indoor temperature
°CDB 16 18 20 22 24
Outdoor temperature
°CDB °CWB
TC IP TC IP TC IP TC IP TC IP
kW kW kW kW kW
-15 -16 7.16 3.53 7.13 3.53 7.10 3.54 6.92 3.54 6.46 3.55
-10 -11 8.19 3.82 8.16 3.82 8.12 3.82 7.91 3.83 7.40 3.84
-5 -7 9.22 4.10 9.18 4.11 9.15 4.11 8.91 4.11 8.32 4.14
0 -2 9.80 4.34 9.76 4.34 9.72 4.35 9.46 4.35 8.84 4.36
5 3 10.94 4.40 10.90 4.40 10.85 4.41 10.56 4.41 9.87 4.44
7 6 11.40 4.43 11.35 4.44 11.30 4.44 11.01 4.44 10.28 4.47
10 8 11.74 4.43 11.69 4.44 11.64 4.44 11.35 4.44 10.59 4.47
15 10 12.22 4.43 12.17 4.44 12.12 4.44 11.80 4.44 11.03 4.47
20 15 13.02 4.44 12.95 4.44 12.90 4.45 12.57 4.45 11.74 4.48
24 18 13.65 4.45 13.59 4.45 13.53 4.47 13.19 4.47 12.31 4.48
¢
Model: ARTH36KMTAP
AFR
m
3
/h
2,070
Indoor temperature
°CDB 16 18 20 22 24
Outdoor temperature
°CDB °CWB
TC IP TC IP TC IP TC IP TC IP
kW kW kW kW kW
-15 -16 8.87 3.74 8.83 3.74 8.80 3.75 8.57 3.75 8.00 3.76
-10 -11 10.15 4.04 10.11 4.04 10.06 4.04 9.80 4.05 9.16 4.07
-5 -7 11.43 4.34 11.38 4.35 11.33 4.35 11.05 4.36 10.31 4.37
0 -2 12.14 4.39 12.09 4.41 12.04 4.41 11.73 4.41 10.96 4.43
5 3 13.56 4.46 13.49 4.46 13.44 4.48 13.10 4.48 12.23 4.49
7 6 14.12 4.49 14.06 4.50 14.00 4.50 13.64 4.51 12.74 4.52
10 8 14.55 4.49 14.50 4.50 14.43 4.50 14.06 4.51 13.13 4.52
15 10 15.14 4.49 15.08 4.50 15.01 4.50 14.63 4.51 13.66 4.52
20 15 16.13 4.50 16.05 4.51 15.98 4.51 15.58 4.52 14.54 4.54
24 18 16.91 4.51 16.83 4.51 16.77 4.52 16.34 4.52 15.26 4.55
¢
Model: ARTH45KMTAP
AFR
m
3
/h
2,160
Indoor temperature
°CDB 16 18 20 22 24
Outdoor temperature
°CDB °CWB
TC IP TC IP TC IP TC IP TC IP
kW kW kW kW kW
-15 -16 11.82 4.92 11.54 4.95 11.26 4.97 11.00 4.97 10.35 4.97
-10 -11 13.13 5.13 12.82 5.15 12.51 5.19 12.21 5.19 11.48 5.19
-5 -7 14.44 5.34 14.10 5.37 13.75 5.39 13.43 5.39 12.64 5.39
0 -2 15.77 5.55 15.39 5.58 15.01 5.61 14.67 5.61 13.80 5.61
5 3 16.88 5.17 16.48 5.20 16.08 5.23 15.70 5.23 14.76 5.23
7 6 17.33 5.16 16.91 5.20 16.50 5.22 16.12 5.22 15.15 5.22
10 8 18.04 5.15 17.62 5.19 17.18 5.21 16.78 5.21 15.78 5.21
15 10 19.25 5.14 18.78 5.16 18.32 5.19 17.90 5.19 16.84 5.19
20 15 20.44 5.12 19.95 5.14 19.46 5.17 19.01 5.17 17.88 5.17
24 18 21.40 5.11 20.89 5.13 20.38 5.15 19.90 5.15 18.71 5.15
¢
Model: ARTH54KMTAP
AFR
m
3
/h
2,160
Indoor temperature
°CDB 16 18 20 22 24
Outdoor temperature
°CDB °CWB
TC IP TC IP TC IP TC IP TC IP
kW kW kW kW kW
-15 -16 13.37 5.07 13.06 5.09 12.73 5.12 12.44 5.17 11.69 5.32
-10 -11 14.86 5.29 14.50 5.31 14.15 5.33 13.81 5.40 12.99 5.55
-5 -7 16.33 5.50 15.94 5.52 15.56 5.56 15.20 5.61 14.29 5.77
0 -2 17.20 5.72 16.79 5.74 16.39 5.77 16.00 5.84 15.04 6.00
5 3 18.41 5.18 17.98 5.21 17.54 5.24 17.13 5.30 16.11 5.44
7 6 18.91 5.17 18.45 5.21 18.00 5.23 17.59 5.29 16.54 5.43
10 8 19.69 5.16 19.21 5.20 18.74 5.22 18.31 5.28 17.23 5.42
15 10 20.99 5.15 20.49 5.17 19.99 5.20 19.53 5.25 18.36 5.40
20 15 22.30 5.13 21.76 5.15 21.23 5.18 20.74 5.24 19.51 5.38
24 18 23.35 5.12 22.78 5.14 22.22 5.16 21.71 5.22 20.42 5.37