Chapter 1 Overview
1.3 Specifications
FUJITSU Storage ETERNUS DX, ETERNUS AF Configuration Guide (Power Synchronized Unit)
Copyright 2017 FUJITSU LIMITED P3AM-8012-10ENZ0
23
1.3 Specifications
Table 1.1 shows the specifications of the power synchronized unit and the AC sensor unit.
Table 1.1 Specifications
Item Specifications
Dimensions (W D H)
Power synchronized unit 440 230 40 (mm) [1U]
AC sensor unit 100 150 40 (mm) [1U]
Weight
Power synchronized unit 4.0kg
AC sensor unit 1.3kg
Power
Voltage AC100 - 120V, AC200 - 240V
Phase Single
Frequency 50Hz/60Hz
Maximum power requirements
AC100 - 120V 3W
AC200 - 240V 7W
Maximum heat generation
AC100 - 120V 11kJ/h
AC200 - 240V 26kJ/h
Connection interface
For ETERNUS DX/AF storage systems RS232C 4
For AC detection AC sensor 2
Number of
connectable
devices
Server UPS unit
Basic 2
Maximum (when AC sensor units
are connected)
16
ETERNUS DX/AF
Basic 4
Maximum (when a cascade
connection is used)
8
Cable length
Between a power synchronized unit
and an AC sensor unit (total)
Max. 100m
Between a power synchronized unit
and the ETERNUS DX/AF
Max. 5m
Between power synchronized units Max. 10m
Conditions to detect AC output
Power consumption
0.1A or less AC output for one second or
more is detected.
Voltage AC100V / AC200V
Phase Single
Support for a duplicated configuration Yes
Environmental condition
Temperature
5 - 40C (during operation)
0 - 50C (during non-operation)
Humidity
20 - 80%RH (during operation)
8 - 80%RH (during non-operation)