4.3 Connecting Cascade Cables
When two power synchronized units are cascaded, use the cascade cable to connect the power synchronized
units.
Cascade cables must be purchased separately.
A connection figure for the cascade cable is shown below.
Figure 4.5 Cascade cable connection
When the power synchronized units are cascaded, the unit that is connected to the server UPS unit is
"power synchronized unit#0".
Do not attach a branch connector or a termination resistor to the CASCADE port or the AC SENSOR port.
Doing so makes operations unstable.
CAUTION
Do
When connecting external (signal, power, etc.) cables, avoid placing stress on
them. Not doing so may damage the cables.
Power synchronized unit#1
Power synchronized unit#0
Server#0
UPS unit for
Server#0
Server#1
UPS unit for
Server#1
Cascade cable
(optional)
Power cord (for AC sensor)
AC SENSOR port
CASCADE port
SENSOR ports