Input signal type
Indoor unit
Input signal type is only "Edge".
Edge
External input and output PCB
The input signal type can be selected.
Signal type (edge or pulse) can be switched by the DIP switch 2 (SW2) on the External input
and output PCB.
Edge
Pulse
The width of pulse must be
longer than 200 msec.