EasyManua.ls Logo

Fujitsu PRIMERGY RX200 S5 - Page 44

Fujitsu PRIMERGY RX200 S5
72 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
44 Options Guide RX200 S5
HDD modules
© cognitas. Gesellschft für Technik-Dokumentation mbH 2009 Pfad: W:\Anwendungsdaten\FCT\tim_local\work\PICHOL\OBJ_DOKU-4105-001.fm
Removing the existing backplane (6x HDD)
Ê Remove all HDD modules from the housing.
Figure 22: Removing the HDD backplane
Ê Disconnect all cables from the HDD backplane (see oval).
Ê Lift the HDD backplane over the metal bars (see arrows) and then remove it
in the direction of the rear of the server.
I Install HDD backplanes in the reverse order.
Installing the backplane (8x HDD)
Ê Place the HDD backplane (8x HDD) on the designated bars on the housing
(see figure 22) and press it down carefully.
Ê Connect all the required cables to the HDD backplane (see section “Cabling
for up to 8 HDD modules” on page 70).

Other manuals for Fujitsu PRIMERGY RX200 S5