RX2530 M5 Operating Manual 21
Product description
Power supply unit (PSU) / Fujitsu battery unit (FJBU)
The server can be equipped with:
Up to two AC PSUs
In its basic configuration the server has one PSU that adjusts automatically
to any mains voltage in the range of 100 V - 240 V (AC PSU Platinum,
450 W) or 200 V - 240 V (AC PSU Titanium, 800 W). Besides the PSU, a
second PSU can be installed optionally to serve as a redundant power
supply. If one PSU fails, the second PSU in the redundant configuration
ensures operation can continue uninterrupted and the defective PSU can be
replaced during operation (hot-plug).The second PSU can be installed
during operation.
Up to two DC PSUs
In its basic configuration the server has one PSU that adjusts automatically
to any mains voltage in the range of -40.5 V - -57 V (DC PSU -48 V, 800 W)
or 200 V- 380 V (HVDC PSU 380 V, 1300 W). Besides the PSU, a second
PSU can be installed optionally to serve as a redundant power supply. If one
PSU fails, the second PSU in the redundant configuration ensures operation
can continue uninterrupted and the defective PSU can be replaced during
operation (hot-plug).The second PSU can be installed during operation.
One AC PSU or DC PSU and one FJBU
Besides the PSU, an FJBU can be installed optionally as a modular UPS.
When power fail happened, the server can operate via FJBU for a while. The
FJBU can be replaced during operation.