106 Operating Manual RX2540 M5
Ambient conditions
All temperature ratings shown are valid for sea level. An altitude derating of 1°C
per 300m to 3048 m is applicable.
Noise level
The acoustic noise values are depending on the system configuration.
Electrical data: 450 W Platinum
Environment class 3K2
Environment class 2K2
EN 60721 / IEC 721 Part 3-3
EN 60721 / IEC 721 Part 3-2
Temperature:
Operation (3K2) 10 °C ... 35 °C
5 °C ... 40 °C (with Cool-safe® ATD 40 °C)
5 °C ... 45 °C (with Cool-safe® ATD 45 °C)
Transport (2K2) -25 °C ... 60 °C
Humidity 10% ... 85% (non condensing)
Condensation during operation must be avoided!
Standard configuration
Sound power level
L
WAd
(ISO 9296)
< 5.6 B (standby)
< 5.6 B (operation)
Sound pressure level at adjacent workstation
L
pAm
(ISO 9296)
< 39 db(A) (standby)
< 39 db(A) (operation)
Rated voltage range 100 V - 240 V
Frequency 50 Hz - 60 Hz
Max. rated current 5.0 A - 2.0 A