EasyManua.ls Logo

Fujitsu PRIMERGY RX300 S5 - Page 11

Fujitsu PRIMERGY RX300 S5
112 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
RX300 S5 Operating manual 11
Preface Features
System board
The features of the system board (D2619) are described in the technical manual
for the system board in relation to the hardware and in the BIOS setup manual.
USB Flash Module (UFM) (option)
The system board is equipped with a UFM slot by the manufacturer.
I The "internal USB stick" and "UFM" slots must not be used in parallel.
Either an internal USB stick or a UFM may be used.
Trusted Platform Module (TPM)
A Trusted Platform Module (TPM) for safer storage of keys can be implemented
as an option. This module enables programs from third party manufacturers to
store key information (e.g. drive encryption using Windows Bitlocker Drive
Encryption).
The TPM is activated via the BIOS system (for more information, refer to the
Fujitsu Technology Solutions BIOS manual).
V CAUTION!
When using the TPM, note the program descriptions provided by the
third party manufacturers.
You must also create a backup of the TPM content. To do this, follow
the third party manufacturer's instructions. Without this backup, if the
TPM or the system board is faulty you will not be able to access your
data.
If a failure occurs, please inform your service about the TPM
activation before it takes any action, and be prepared to provide them
with your backup copies of the TPM content.
Slots for expansion cards
The server can be flexibly expanded via seven slots (two PCIe Gen2 x8 and five
PCIe Gen2 x4). PCIe Gen2 doubles the bandwidth of currently existing PCIe
busses and allows improved system performance.
One of these slots (slot 1) is occupied with one of two possible SAS/SATA RAID
controllers.

Table of Contents

Other manuals for Fujitsu PRIMERGY RX300 S5

Related product manuals