EasyManua.ls Logo

Fujitsu PRIMERGY RX300 S5 - Page 72

Fujitsu PRIMERGY RX300 S5
112 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
72 Operating manual RX300 S5
Switching the server on and off Starting up and operation
I If the operating system does not switch the server off automatically, press
the On/Off button for at least four seconds and/or send a corresponding
control signal.
Other On/Off options
Besides the On/Off button, the server can be switched ON and OFF in the
following ways:
Timer-controlled switch-on/off
Using the ServerView Operations Manager or iRMC S2, you can configure
that the server is switched on/off controlled by timer.
Ring indicator
The server is switched on by an internal or external modem.
Wake up On LAN (WOL)
The server is switched on by a command via the LAN (Magic Packet
TM
).
After power failure
The server automatically reboots following a power failure (depending on the
settings in the BIOS or in iRMC S2).
Power button override
The system can be switched off (hard power off) by holding down the On/Off
button (approximately 4 - 5 seconds).
V CAUTION!
There is a risk that data may be lost.
iRMC S2
iRMC S2 offers various options for switching the server on and off, e.g. via
the Power On Off page of the iRMC S2 Web interface.

Table of Contents

Other manuals for Fujitsu PRIMERGY RX300 S5

Related product manuals