114 Operating Manual RX600 S5
Hot-plug components CSS components
© cognitas. Gesellschft für Technik-Dokumentation mbH 2010 Pfad: C:\Programme\FCT\tim_app\tim_local\work\PICHOL\OBJ_DOKU-4891-003.fm
Operating the expansion card
Ê Insert the expansion card fastened to the removal tool in the PCI slot.
Ê Close the slot lock (see pos. #2 in figure 28 on page 109) by folding it down.
Make sure that the slot lock engages.
Ê If necessary, connect the cables on the expansion card.
Ê Activate the expansion card using either the relevant PCI hot-plug software
or by pressing the light-pipe switch (see pos. #1 in figure 28 on page 109).
The light-pipe switch flashes green. The slot is in the enable sequence.
Ê Wait until the light-pipe switch is constantly green.
The slot is now powered on.
I If the light-pipe switch continues to flash, an error has occurred.
Remove the expansion card and repeat the procedure as described
above.
Ê Close the server (see "Opening/Closing the server" on page 134).