24 Operating Manual RX600 S5
Technical data Preface
© cognitas. Gesellschft für Technik-Dokumentation mbH 2010 Pfad: C:\Programme\FCT\tim_app\tim_local\work\PICHOL\OBJ_DOKU-4884-003.fm
Dimensions / Weight
Ventilation clearance
At least 200 mm on the front and rear.
Ambient conditions
Condensation during operation must be avoided!
Noise level
Rack (W x D x H) 482.6 mm (Bezel) / 444.8 mm (Body) x 770.0 mm x
176.0 mm
Mounting depth rack 728 mm
Height unit rack 4 U
19" rackmount Yes
Mounting cable depth
rack
100 mm (1000 mm rack recommended)
Weight min. 32 kg; max. 46 kg (actual weight may vary
depending on configuration)
Rack integration kit rack integration kit as option
I Rack integration kit is standard for the
japanese market.
Environment class 3K2
Environment class 2K2
EN 60721 / IEC 721 Part 3-3
EN 60721 / IEC 721 Part 3-2
Temperature:
Operation (3K2) 10 °C .... 35 °C
Transport (2K2) -25 °C .... 60 °C
Humidity 10% ... 85% (non condensing)
Sound power level L
WAd
(ISO 9296) < 6.2 B (standby)
< 6.6 B (operation)
Sound pressure level at bystander position L
pAm
(ISO 9296) (at < 23 °C)
< 46 dB(A) (standby)
< 51 dB(A) (operation)