TX120 S3 Operating Manual 27
Functional overview
Dimensions / Weight
Ventilation clearance
At least 200 mm on the front and rear.
Ambient conditions
Condensation during operation must be avoided!
Noise level
Upright operating
position (W x D x H)
180 mm x 343 mm x 360 mm (including feet)
Horizontal operating
position (W x D x H)
340 mm x 343 mm x 98 mm
Weight up to 10 kg
Weight notes Weight may vary depending on actual configuration
Environment class 3K2
Environment class 2K2
EN 60721 / IEC 721 Part 3-3
EN 60721 / IEC 721 Part 3-2
Temperature:
Operation (3K2) 10 °C ... 35 °C
Transport (2K2) -25 °C ... 60 °C
Humidity 10% ... 85% (non condensing)
Sound power level L
WAd
(ISO 9296) < 4.3 B (standby)
< 4.7 B (operation)
Sound pressure level at adjacent workstation
L
pAm
(ISO 9296)
< 27 dB (A) (standby)
< 32 dB (A) (operation)