TX2560 M2 / RX2560 M2
Operating Manual 27
Dimensions / Weight
Ventilation clearance
There must be a clearance of at least 200 mm in front of and behind the server
to ensure adequate ventilation of the subsystem.
Ambient conditions
Condensation during operation must be avoided!
Tower (W x D x H) 177 mm x 777 mm x 456 mm
Rack (W x D x H) 482.6 mm (bezel) / 448 mm (body) x 736 mm x
177 mm
Height unit rack 4 U
Mounting Depth Rack 700 mm
19" rack mount Yes
Weight 22 - 35.5 kg
Weight notes Weight may vary depending on actual configuration
Rack mounting kit Rack mounting kit as option
Environment class 3K2
Environment class 2K2
EN 60721 / IEC 721 Part 3-3
EN 60721 / IEC 721 Part 3-2
Temperature:
Operation (3K2) 5°C ... 40°C (with Fujitsu ATD 40°)
5°C ... 45°C (with Fujitsu ATD 45°)
10°C ... 35°C (without Fujitsu ATD)
Transport (2K2) -25°C ... 60°C
Humidity 10% ... 85% (non condensing)