3-4-3 DayOSetting
SetthedayoftheweekofwhichWeeklyTimeristobe
temporarilydisabled.Whenthesetdayhaspassed,the
setting is cleared.
(1) Touchthe[DayOSetting]onthe“WeeklyTimerSet-
ting” screen.
(2) “DayOSetting”screenisdisplayed.Whenthedayof
the week of which Weekly Timer is not to be performed
is touched, a check mark is displayed.
(1) (2)
Back
Enable Schedule [Schedule 1]
[Set]
[None]
Schedule Setting
Day Off Setting
Weekly Timer Setting
:Day Off
Day Off Setting
Cancel OK
Sun Mon Wed ThuFri SatTue
When setting is complete, touch the [OK]. After the set-
ting complete screen is displayed, the display returns to
the “Weekly Timer Setting” screen.
3-5 SpecialSetting
(1) Touch the [Special Setting] on
the “Main Menu” screen.
Monitor
Next
Page
Page 1/ 2
Main Manu
Air Flow Direction
Setting
Weekly Timer
Setting
Auto Off Timer
Setting
Special Setting
(2) “Special Setting” screen is displayed. When the screen
has multiple pages, they can be switched by touching
the [Next Page] or [Previous Page].
Back
Special Setting
Set Temp.
Range Setting
Set Temp.
Auto Return
Anti Freeze
Economy
Next
Page
Page 1/ 2
Back
Previous
Page
Page 2/ 2
Special Setting
Human Sensor
Setting
Emergency Heat
Fan Control for
Energy Saving
Away Setting
Thefollowingcontentsareset:
(*:Itemsthatindoorunitdoesnotsupportarenotdis-
played.)
• Economy:
Thetemperaturesettingisosetautomaticallyovera
certain period of time. The power consumption is sup-
pressed by setting the temperature high during cooling
and low during heating.
• SetTemp.AutoReturn(foradministrator):
Even if the temperature setting is changed during Cool
or Heat mode operation, after the set time, the tem-
perature automatically returns to the set temperature.
• SetTemp.RangeSetting(foradministrator):
Power consumption by excessive temperature setting
is suppressed by restricting the temperature setting
range for each operation mode of Auto, Cool/Dry, or
Heat.
• AntiFreeze*(foradministrator):
Anti Freeze is a function that performs low tempera-
ture heating operation to prevent freezing of water
lines and equipment, when air conditioning operation
iso,inregionswhereoutsidetemperaturemaydrop
below freezing.
If water lines are far from the unit or within exterior
walls, this function may not provide enough anti freeze
protection.
• AwaySetting(foradministrator):
Set the operation start temperature at Unoccupied. To
use this function, “Used” must be set by “R.C. Sensor
Setting”.Referto[3-8InitialSetting]→[3-8-5R.C.
Sensor Setting].
• HumanSensorSetting*(foradministrator):
“Human Sensor” detects the absence of a person in
the room and performs the following energy saving op-
eration. For details of “Human Sensor”, refer to indoor
unit operation manual.
[Auto Saving]
When the absence continues for the set time, the
operation switches to energy saving operation.
[AutoO]
When the absence continues for the set time, indoor
unit operation stops.
• FanControlforEnergySaving*(foradministrator):
When the set temperature is reached during cooling
operation, the fan operates intermittently and power is
saved.
• EmergencyHeat*:
Auxiliary heater will be primary heater, and the outdoor
unit will stop.
When the item to be set is touched, the display switches
to each setting screen. When each setting is complete
or canceled, the display returns to this screen. When
[Back] is touched, the display returns to the “Main
Menu” screen.
3-5-1 Economy
On/OofEconomy
(1) Touch the [Economy] on the “Special Setting” screen.
(2) “Economy”screenisdisplayed.Touchthe[On]or[O]
on the “Economy” screen.
(1) (2)
Back
Special Setting
Set Temp.
Range Setting
Set Temp.
Auto Return
Anti Freeze
Economy
Next
Page
Page 1/ 2
Economy
Cancel OK
On
Off
When you touch the [OK], the data is transmitted to the
indoor unit, and then the display returns to “Special Set-
ting” screen.
3-5-2 SetTemp.AutoReturn(foradministrator)
(1) Touch the [Set Temp. Auto Re-
turn] on the “Special Setting”
screen. When the “Password
Verication”screenisdis-
played, enter the password
and touch the [OK].
Back
Special Setting
Set Temp.
Range Setting
Set Temp.
Auto Return
Anti Freeze
Economy
Next
Page
Page 1/ 2
EnabletheSetTemp.AutoReturn
(2) “Set Temp. Auto Return” screen is displayed. Touch the
[Enable/Disable] on the “Set Temp. Auto Return” screen.
(3) “Enable/Disable” screen is displayed. Touch the [Enable]
on the “Enable/Disable” screen.
(2) (3)
60min. / 84°
F
60min. / 74°
F
Enable /Disable [Disable]
Set Temp. Auto Return
Cancel OK
Cool/Dry
Heat
Return Time / Return Temp.
Enable/Disable
Cancel OK
Enable
Disable
En-13