Applythesetting
(8) After setting is complete,
touch the [OK] on the “Back-
light Setting” screen.
After the setting change is
displayed, the display returns
to the “Preference” screen.
Enable/Disable [Enable]
[30s]
[2]
Automatic Off Time
Brightness
Backlight Setting
Cancel OK
3-7-3 Contrast Setting
(1) Touch the [Contrast Setting] on the “Preference” screen.
(2) “Contrast Setting” screen is displayed. Adjust the con-
trast with [
] or [ ].
(1) (2)
Back
Preference
Panel
Calibration
Backlight
Setting
Contrast
2
3
4
5
1
Contrast
Cancel OK
When the [OK] is touched, after the setting change
screen is displayed, the display returns to the “Prefer-
ence” screen.
3-8 Initial Setting (for administrator)
Perform this setting at installation. The setting can also be
changed after installation.
(1) Touch the [Initial Setting] on the “Main Menu” screen.
(2) When“PasswordVerication”screenisdisplayed,enter
the Password (or Installer Password) and touch [OK].
(1) (2)
Monitor
Previous
Page
Page 2/ 2
Main Menu
Summer Time
Setting
Initial Setting Maintenance
Preference
0
CL
5
1
6
2
7
3
8
4
9
Cancel OK
Password Verification
Enter Current Password
(3) If the password is entered correctly, the “Initial Setting”
screen is displayed. The screen has 4 pages which
are switched by touching the [Next Page] or [Previous
Page].
Back
Next
Page
Page 1/ 4
Initial Setting
Language Setting Date Setting
R.C.Group
Name Setting
Temp. Unit
Setting
Back
Previous
Page
Page 2/ 4
Initial Setting
R.C. Sensor
Setting
Password Setting
Display Item
Setting
Master Indoor
Unit Setting
Next
Page
Back
Previous
Page
Page 3/ 4
Initial Setting
RC Master/
Slave Setting
I.U. Display
Number Setting
Deadband Setting
Optimum Start
Setting
Next
Page
%DFN
3UHYLRXV
3DJH
3DJH
,QLWLDO6HWWLQJ
/HDG/DJ
6HWWLQJ
Thefollowingcontentsareset.(♦:forinstaller)
(*:Itemsthatindoorunitdoesnotsupportarenotdis-
played.)
• LanguageSetting:
The displayed language is switched. The displayable
languages are English (factory setting), French, Ger-
man, Spanish, Polish, Russian, Italian, Portuguese,
and Turkish.
• DateSetting:
The date and time display format are set. When the
poweristurnedo,thedateandtimedataholdtime
by built-in battery is approximately 7 days. When the
poweristurnedoforlongerthanthis,thedateand
time must be reset.
• Temp.UnitSetting:
The temperature display unit is switched to “°C” or “°F”.
Factory settings is “°C”.
• R.C.GroupNameSetting:
The remote controller group name can be set or
changed.
• RCSensorSetting*:
This setting uses the sensor of this unit to sense the
room temperature. The room temperature can be
sensed at a position, closer to the person than the
indoor unit sensor. Factory settings is “Not Used”.
• MasterIndoorUnitSetting:♦
• PasswordSetting:
The password setting and changes can be performed.
In addition, password request to the following setting
items can be set.
• AutoOTimer(3-3)
• Weekly Timer (3-4)
• Set Temp. Auto Return (3-5-2)
• Set Temp. Range Setting (3-5-3)
• Anti Freeze* (3-5-4)
• Away Setting (3-5-5)
• Human Sensor Setting* (3-5-6)
• Fan Control for Energy Saving* (3-5-7)
• Initial Setting (3-8)
• Maintenance (3-9)
• DisplayItemSetting:
Display of the Filter sign and Room temp. can be
switched between Visible and Invisible.
• RCMaster/SlaveSetting♦
• DeadbandSetting:
Set the deadband value. The deadband can be set
within the 2ºF to 9ºF (1ºC to 4.5ºC) range. Set the
deadband value only to the Master Indoor Unit. (Set-
tingsarenotreectedevenifthedeadbandvalueis
set to other indoor units.)
Depending on a model of the indoor unit, the dead-
band is set on the indoor unit side. In this case, the
Deadband Setting is not displayed on this unit. If you
want to change the setting, consult an authorized ser-
vice personnel.
• OptimumStartSetting:
When this function is set to On, the indoor unit per-
forms advance operation so that the set temperature
is reached when occupied begins by schedule. To
use this function, schedule must be set. Refer to [3-4
Weekly Timer Setting].
• I.U.DisplayNumberSetting*♦
• LeadLagSetting:
When connecting multiple indoor units in 1 R.C.Group,
they take turns stopping 1 or 2 at a time for backup.
Factory setting is “disabled”.
When the item to be set is touched, the display switches
to each setting screen. When each setting is complete
or canceled, the display returns to this screen. When
[Back] is touched, the display returns to the “Main Menu”
screen.
En-18