2. WIRING
2-10
2.3.3 Connecting power cable
Fabricate the power cable DPYCY-4 (Japan Industrial Standard (JIS)) or equivalent (local
supply.)
40
5
100
Vinyl sheath Armor
TB-B1
FV5.5-4
1
2
Conductor
S = 4 mm
= 2.55 mm
2
Armor
Vinyl sheath
15.9 mm
DPYCY-4, sectional view
Fabricating of power cable
Note: Change connection of white wire at the TB-B1 according to ship’s mains. And then,
replace the fuse appropriately. On the stickers at the terminal board and back of the
front lid of the transceiver unit, change the mark position for the used fuse.
Ship’s mains Fuse
100/110/115 VAC 7 A 125 V
200/220/240 VAC 4 A 250 V
TB-B1
1234567
Ship's mains
100V
115V
200V
220V
240V
White
Connections at TB-B1
2.3.4 How to unplug the XH connector
If making a wrong connection of XH connector, use the XH connector puller to unplug the
XH connector.
XH connector
puller
XH connector
XH connector puller