3. ADJUSTMENT
3-4
3.3 Setting for External Equipment
Do the following settings depending on the external equipments connected. Open the
System menu referring to the previous page.
**
SYSTEM MENU
**
(RANGE CTRL: U/D, GAIN CTRL: L/R)
[MENU MODE] : SONAR SOUNDER MARKS SYSTEM
DIMMER : 10
DISP SELECT : TEMP CURRENT
HEADING ADJ : 0°
AUTO RETRACT : OFF (OFF, 5-16kt)OFF
SPEED MESSAGE : ON OFF
EXT KP SYNC : OFF ON
AUTO TRAIN SPD : LOW HIGH
AUTO TILT SPD : LOW HIGH
UNIT : METERS FEET FATHOMS PA/BRA
SHIP’S SPD/BR :
LOG/GYRO
CURRENT NAV DATA
GYRO+NAV
LOG PULSE : 200 400
PORT1 BAUDRATE : 19200 9600 4800 2400
PORT1 FORMAT : NMEA CIF
PORT2 BAUDRATE : 19200 9600 4800 2400
PORT2 FORMAT : NMEA CIF
NAV DATA : GPS LC DR ALL
COMBI SCALE : RIGHT LEFT
SUB TEXT INDI : OFF ON
LANGUAGE : ENGLISH (JAPANESE) ESPANOL DANSK
NEDERLND FRANCAIS ITALIANO
(KOREAN)
TEST : SINGLE CONTI PANEL COLOR
: PATTERN SIO ECHO-1 ECHO-2
ECHO-3 ECHO-4
SET TO DEFAULT : EXECUTE
PRESS [MENU] KEY TO EXIT
= Items should be set after the installation
System menu
EXT KP SYNC
Select using or not using the external keying pulse (See “2.5 Synchronizing Transmission
with Other Equipment” on page 2-16.)
1. Rotate the [RANGE] control to select EXT KP SYNC.
2. Rotate the [GAIN] control to choose OFF or ON.
OFF: Not using the external keying pulse
ON: Using the external keying pulse.