1. MOUNTING
1-18
10. Remove the Jubilee clip located at the base of the transducer (1) cable and four
M4 flat-head Phillips screws at the top side of the transducer (1).
11. Pass the transducer cable through the shaft from the flange side.
12. Apply the Liquid Gasket TB1121 to the top side of the transducer evenly.
13. Apply the Liquid Gasket TB1121 to the thread part of hex. bolt (15) with seal wash-
er (16) and use them to fasten the transducer.
Check that the fore mark on the shaft is aligned with the projection at the bottom
of the transducer.
14. Pass the flat washer (8), gasket (7), washer (8), and the gland (19) onto the trans-
ducer cable.
Jubilee clipJubilee clip
Do not remove
this screw.
Remove these
four screws.
Removing Jubilee clip
Removing flat-head Phillips screws
The fore mark on the shaft
Align them.
The projection on the transducer
Bottom view