DSC60
B4-7
3.2 Setting for the connection with FS-75/1562/5000 and DP-6
TX/RX control data exchange between Furuno radio units is made normally by MIF
protocol through the RS-232C connections with factory-default setting.
Connection with FS-5000 and DP-6
Connection with FS-75/1562 and DP-6
The DIP switches on CONTROL/MODEM board of DSC-60 are set as follows:
RT: S4 (Selection of data format for the communication with RT)
- S4-1 and 2 : ON (RS-232C)
- S4-3 and 4 : OFF (RS-232C)
NBDP: S3 (Selection of data format for the communication with NBDP)
- S3-1 and 2 : ON (RS-232C)
- S3-3 and 4 : OFF (RS-232C)
Note) Related settings
Pressing [#/SETUP] key reveals “Setup menu” screen. Select SYSTEM, and set RT
PORT and NBDP PORT.
- RT PORT ->>> MIF
- NBDP PORT ->>> ON
Furthermore, priority setting must be made on FS-75/1562:Ver.07 and after.
Not necessary on FS-5000.
FS
-75/1562 Set to setting No.9928:1
FS-75/1562
Setting of 9928
Priority
0: Main unit takes priority. 1: Remote control takes priority.
1 DSC Distress alert DSC Distress alert
2 2182kHz (Main unit) DSC other than distress
3 DSC other than distress Remote TEL (DSC)
4 Remote TEL (DSC) NBDP
5 NBDP 2182kHz (Main unit)
6 Main unit Main unit
DSC-60
[RT]
[NBDP]
DP-6
FS-5000C
[REM-1/2/3]
[REM-1/2/3]
[REM-B] [REM-A]
#2-SD
#3-RD
#2-SD
#3-RD
DSC-60
[RT]
[NBDP]
DP-6
DB-120
FS-75/1562
[REM]
[REM-B] [REM-A]
REM-A
PCB
#2-SD
#3-RD
#2-SD
#3-RD