4-18
4.6 Setting for NBDP (DP-6)
When the NBDP DP-6 is connected to the radiotelephone, the following setting must be
carried out.
Setting on DP-6
1. On the DP-6, press [F6], and enter the password for system setting. The setting must
be as below.
System
Set up Lock Change Default
Slave Delay 5 msec (0 - 50msec)
BK Timing Pre Tone 10 msec (0 - 100msec)
Post Tone 0 msec (0 - 20msec)
Mute Timing Pre BK 0 msec (0 - 20msec)
Post BK 0 msec (0 - 20msec)
Mdem Output Level
0
dBm (-30 - +10 dBm)
MIF Tune OFF ON
Freeze OFF ON
AGC OFF ON
Emission OFF ON
TX/RX MSG Save OFF ON
Edit Before Sending OFF ON
Timer System OFF UTC STM JST
Time & Date
Display Mode Normal Reverse
Self Test
*
*
*
*
*
*
*
*
*
*
• Slave Dela
ut Lervel
0 dBm
• MIF Tune
ON
• Freeze
ON or OFF
• AGC
ON
• Emission
ON
[F6] System Setup Menu
2. Press [F5] and enter the answerback code and the ID.
Setting on FS-1503
⋅
9908 (TLX usage): 0 (TX/RX)
⋅
9909 (TLX RX bandwidth): 1 (Narrow)-------- Optional 0.4 kHz filter required
⋅
9910 (System delay): 10 msec
⋅
9921 (THRU signal to couper): 0 (Limited)
⋅
9924 (Remote signal format): 0 (MIF)