5. INITIAL SETTINGS
8
5. Press the [NU/CU ENT] key.
6. Press the [MENU ESC] key.
Manual DGPS setup
Enter four digit ID number, frequency and baud rate of station, referring to the DGPS list in
the GP-80 operator's manual.
1. Press [MENU ESC] [9] and [7] to display the DGPS SETUP menu.
2. Press
!
or
"
to select DGPS MODE and press
#
to select On.
3. Press
!
or
"
to select Ref. Station.
4. Press
$
to select Man.
5. Enter four digit ID number. You can clear an entry by the [CLEAR] key. If the number
entered is invalid, the buzzer sounds and the message "INVALID ID" appears on the
display for three seconds.
If there is no ID number, press the [NU/CU ENT] key.
6. Press the [NU/CU/ENT] key.
7. Enter frequency in four digits (283.5 kHz to 325.0 kHz).
8. Press the [NU/CU ENT] key. "Band Rate" appears in reverse video.
9. Press
#
or
$
to select band rate; 25, 50, 100 or 200bps.
10. Press the [MENU ESC] key.
DGPS Operation checking
1. Press [MENU ESC] and [7].
2. Press [
] several times to display the following.