EasyManua.ls Logo

Furuno GP-80 - Interface Documentation; Output Schematic Diagram (Talker); Output Drive Capability; Input Schematic Diagram (Listener)

Furuno GP-80
37 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
5. INITIAL SETTINGS
18
Interface Documentation
"DATA1" Port
! IEC 61162-1/NMEA 0183 Ver. 1.5 Output
Output Schematic Diagram (Talker)
1
2
6
6
7
8
DATA 1
J5
TD-A
TD-B
FL14
FL13
MJ-A6SRMD
20P8147
U35
SN75ALS172
Output Drive Capability
Max. 10mA
IEC 61162-1 output subject to the standard of IEC 61162-1 First edition 1995-11.
Output Sentence is described on page 8 and 9. Each sentence is output at the interval
entered.
! NMEA 0183 Input
Input Schematic Diagram (Listener)
1
J5
2
3
4
5
6
RD-H
RD-C
1
3
4
5
FL11
DATA 1
20P8147
MJ-A6SRMD
R77
470
FL12
CR13
1SS226
PC-400
U17
+5V
R64
2.2K
Load Requirements
Isolation: opto coupler
Input Impedance: 470
Max. Voltage:
±
15V
Threshold: 3mA (In case of FURUNO device talker connection)
Input Sentence is described on page 11.

Other manuals for Furuno GP-80