B–4
Output signal (contact closure signal)
J10 (WPT alarm) J11 J12
Pin no. Designation Pin no. Designation Pin no. Designation
#1 Alarm signal #1 Alarm signal #1 Alarm signal
#2 Alarm signal #2 Alarm signal #2 Alarm signal
#3 GND #3 GND #3 GND
Selection of output data format
The output data format is selectable by changing a jumper block; A for RS-422 and B for
NMEA. For example, to select NMEA for J4, change the jumper block from A to B on J401
and J402. Do the same on J5 thru J9.
J10 (WPT alarm) J11 J12
Output Jumper Output Jumper Output. Jumper
J4 J401/J402 (A) J5 J501/J502 (A) J6 J601/J602 (A)
J7 J701/J702 (A) J8 J801/J802 (A) J9 J901/J902 (B)
Default of jumper setting is shown in parenthesis.
Maintenance
Fuse replacement
If the fuse blows, find the cause of the problem before replacing it. Do not use a fuse rated
more than 0.5A, since it may cause more serious damage to the equipment.
Self test 1
The unit performs an internal self-check in the following sequence each time power is turned
on.
1) LEDs CR7 to CR10 blink twice every 2 seconds.
2) ROM and RAM are tested.
3) LED CR13 blinks every second for normal operation. If an error is detected during the
test, the corresponding LED is turned on.
When CR7 is on, ROM is defective.
When CR8 is on, RAM is defective.