13
2. WIRING
2.1 System Wiring
Remote Alarm
Panel (RAP)
VR-3016
Junction Box (JB)
IF-8530*
Junction Box (JB)
IF-8530 (max.2)
HUB
or
24 VDC
DPYC-1.5
DPYC-1.5
DPYC-2.5
DPYC-1.5
IEEE1394 cable
(20m, 25m or 30m, w/ armor)
Analog (max.16ch)
TTYCS-1
Analog (max.16ch)
TTYCS-1
Digital (max.64ch)
TTYCS-1
Digital (max.64ch)
TTYCS-1
Serial (1ch)
Serial (max.8ch)
TTYCS-1 x 6*
1
TTYCS-1Q x 2*
2
TTYCS-1 x 6*
1
TTYCS-1Q x 2*
2
GPS
Speed log
Echo sounder
Autopilot
Engine telegraph
Steering gear
M/E remote system
Main air compressor
Bow thruster
Shell door system
Watertight doors
Fire doors
Anemometer
Fire detection
Main alarms
Others
TTYCS-4
TTYCS-4
(max. 6 ch)
TTYCS-1
(max. 2 ch)
TTYCS-4
LAN cable
STP(CAT5)
LAN cable
STP(CAT5)
Data Recording Unit (DRU)
VR-5020-9G
24 VDC
100-230 VAC
Data Collecting
Unit (DCU)
VR-3010
Radar I/F
RI-3010*
Waterproof MIC
VR-3012W
Bridge MIC
VR-5011
VHF Audio
Radar
IEC61162
Serial data
Alarm Monitoring
System
No. 1
Radar
No. 2
Radar
PC
Live Player V4
VR-3020
: Standard supply equipment and cable
:Optional supply equipment and cable
:Local supply equipment and cable
*: Optiopnal with VR-3000S
Radar Video
SW Interface
IF-1000RVC
*3
*3
*3
Cable names (Japan Industrial Standard,
equivalent may be used) are shown along
cable lines together with number of cables
required.
*
1
: IEC 61162-1
*
2
: IEC 61162-2
*
3
: KB-HD152K or 3COX-2P-6C
3C2V or 5C2V
(max. 4 ch)
VHF I/F
IF-5200