English
8
67
Remove the spout holder (A2) by loosening the two Allen
screws (H2).
Then proceed to remove seal (E2) using a screw driver.
After removing the seal undertake to clean the slot and
then re-assemble the new seal taking care to insert it with
the chamfered part turned upwards towards the unit itself.
8.3 Purifier Regeneration
Regenerate the purifier at
the intervals listed below:
HARDNESS °F 8 LITRE PURIFIER 12 LITRE PURIFIER
From 00 to 20
regeneration after 1100 l regeneration after 1600 l
From 21 to 30
regeneration after 850 l regeneration after 1250 l
From 31 to 40
regeneration after 650 l regeneration after 950 l
From 41 to 50
regeneration after 450 l regeneration after 650 l
These regeneration
instructions are valid only
providing the purifier is as
that indicated in the figures.
Should it fail to correspond
proceed as indicated in the
instructions attached to the
purifier itself.
A3 Water Inlet
B3 Water Output
C3 Inlet Tap Lever
D3 Output Tap Lever
E3 Depressurizer Pipe
F3 Regeneration Tube
G3 Cover Knob
Place the empty 2 litre container under pipe E3. Shift
levers C3 and D3 from left to right and remove the cover
by loosening knob G3, pour in 1.5 kg of sodium chloride
(coarse cooking salt) into the 8-litre purifier and 2 kg into
the 12-litre type.