GALaxy eHydro Elevator Controller Section 6 Main CPU Faults & Detailed Faults
6-96
Table 6-3: Faults from the COP Board Devices on the CTCAN Serial Port
Fault
Description
Possible Cause/Suggested Fix
FET Open Blue
Car Call Board FET open blue
• Faulty LED signal from RGB Board. Look at detailed
car faults log to determine device. 'dev' gives you
address for global CAN device, 'dv2' gives you local
CAN device and 'pf1' the number for the IO location
within the local board.
FET Open Grn
Car Call Board FET open
green
• Faulty LED signal from RGB Board. Look at detailed
car faults log to determine device. 'dev' gives you
address for global CAN device, 'dv2' gives you local
CAN device and 'pf1' the number for the IO location
within the local board.
FET Open Red
Car Call Board FET open red
• Faulty LED signal from RGB Board. Look at detailed
car faults log to determine device. 'dev' gives you
address for global CAN device, 'dv2' gives you local
CAN device and 'pf1' the number for the IO location
within the local board.
FET Short Grn
Car Call Board FET short
green
• Faulty LED signal from RGB Board. Look at detailed
car faults log to determine device. 'dev' gives you
address for global CAN device, 'dv2' gives you local
CAN device and 'pf1' the number for the IO location
within the local board.
FET Short Red
Car Call Board FET short red
• Faulty LED signal from RGB Board. Look at detailed
car faults log to determine device. 'dev' gives you
address for global CAN device, 'dv2' gives you local
CAN device and 'pf1' the number for the IO location
within the local board.
FET Shrt Blue
Car Call Board FET short blue
• Faulty LED signal from RGB Board. Look at detailed
car faults log to determine device. 'dev' gives you
address for global CAN device, 'dv2' gives you local
CAN device and 'pf1' the number for the IO location
within the local board.