GALaxy eHydro Elevator Controller Section 6 Main CPU Faults & Detailed Faults
6-101
DRF: Front Door Flag
RDF: Rear Door Flag
0 = Door Closed
1 = Door Opening
2 = Door Dwelling
3 = Door Closing
4 = Door Nudging Closed
0 = Door Closed
1 = Door Opening
2 = Door Dwelling
3 = Door Closing
4 = Door Nudging Closed
DPR: Direction Preference Flag
DIR: Car Direction Flag
0 = None
1 = Up
2 = Down
0 = None
1 = Up
2 = Down
EMP: Emergency Power Flag
0 = Not on Emergency Power
1 = On Emergency Power Waiting
2 = On Emergency Power Waiting with Doors
Open
3 = On Emergency Power Returning Home
4 = On Em. Power Returned Home with Doors
Open
5 = On Em. Power Returned Home with Doors
Closed
6 = On Emergency Power and Selected to Run
7 = On Emergency Power waiting with Doors
Closed
MED: Medical Emergency
0 = No Medical Emergency Service
1 = Recall Car to Medical Emergency Recall
Floor
2 = At Return Floor with Door Open (Return
Complete)
4 = On EMS Car Call Service
5 = On EMS Car Hold Service (key off but not at
the recall floor)
CBL: Code Blue Flag
0 = No Code Blue
1 = Recall to Emergency Floor
2 = At Code Blue Floor
3 = At Code Blue Floor with Door Open
4 = Finished Code Blue

Table of Contents