EasyManua.ls Logo

GAL GALaxy eHydro - Page 218

GAL GALaxy eHydro
248 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
GALaxy eHydro Elevator Controller Section 7 Main CPU Adjustable Variables
7-33
Table 7-7: Group Options
Field Variable
Min
Max
Initial
Units
Description
ATT Pref Time
0
60
0
Sec
Attendant ETA Preference Time. When set to
nonzero, the car not on attendant service has this
time added to its ETA time. This causes the attendant
car to be given a preference for the hall call.
CB Button Loc
0
2
0
-
Code Blue Location.
0 = CB on CB,
1 = CB on HCB,
2 = CB on IR
CB Car 2
0
Number
Cars
0
Car
Code Blue Car #2. When a Code Blue call is initiated,
this will be the car to be sent to respond in the event
that first 'Code Blue Car' is not available, see
variables 'Code Blue Car' and 'CB Rcll Any Car' for
more options.
CB IR Penalty
0
60
10
sec
IR Car Code Blue Penalty Time. It is used to calculate
and give preference to cars in fully automatic
operation
CB Rcl anycar
0
1
0
-
Code Blue Recall Any Call.
0= Disable
1 = Enables dispatcher to recall any car If Code Blue
Cars 1 and 2 are not available.
If you want to select any car as your primary option,
make Code Blue Car and Code Blue Car #2 equal to
zero and enable this setting.
CB Req IndCar
0
1
0
-
Code Blue Request Independent Car. Code blue
request for car on independent operation. Set to 1 in
dispatcher in all cars so the car could be requested
(flash EML) if the car is in independent mode.
CB Sel IR Car
0
1
0
-
Code Blue Over IR Car
CB SRiser Car
0
Number
Cars
0
Car
Code Blue Second Riser Car Select.

Table of Contents