GALaxy eHydro Elevator Controller Section 7 Main CPU Adjustable Variables
7-45
Table 7-8: Color Lights
Field Variable
Min
Max
Initial
HC On Brght
0
100
100
Hall Call On Brightness for LED Hall Call Buttons.
Used only with GAL serial hall button fixtures.
HC Sec Bright
0
100
100
Hall Call Security Brightness for Secured Floors.
HC Sec Color
0
15
15
Select what color to illuminate the hall buttons
when the system is on security. Used only with GAL
serial hall button fixtures.
0 Based on Parameters
1 Red
2 Orange
3 Yellow
4 Chartreuse
5 Green
6 Aquamarine
7 Cyan
8 Azure
9 Blue
10 Violet
11 Magenta
12 Rose
13 Rose White
14 Warm White
15 Cool White
HC Sec Ctl
0
7
0
Hall Call Button Security Light.
1 = Invert security,
+2 = Flash security,
+4 = Master Security Enabled
HCD Off Brght
0
100
20
Hall Call Light Off Brightness for LED Hall Call
Buttons. Used only with GAL serial hall button
fixtures.