EasyManua.ls Logo

GAL GALaxy eHydro - Page 68

GAL GALaxy eHydro
248 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
GALaxy eHydro Elevator Controller Section 5 LCD Interface
5-4
Table 5-0: Elevator Service
= (SAF) Safety String
= (LPR) Low Pressure
= (INS) Inspection
= (HOT) Hot Oil Operation
= (RST) Reset Mode
= (ADO) Auto Door Off
= (TST) Test Mode Service
= (ROT) Riot Control
= (HSU) Hoistway Setup
= (CEO) Car Sw Elevator Off
= (FFS) Fire Fighter's Stop Switch
= (HEO) Hall Sw Elevator Off
= (MRS) Machine Room Stop Switch
= (COF) Car Off Switch
= (MOS) Motion Stop
= (RTL) Return To Lobby
= (AFS) At Floor Shutdown
- (IND) Independent Service
= (CMF) Comm Fail
= (VIP) Priority VIP Service
= (DCF) Door Close Fail
= (LWC) Calibrate Load Weigher
= (DPS) Door Protection Svc
= (JAK) Jack Reset Service
= (STA) Stalled Out Of Svc
= (OVL) Load Weigh Overload
= (Low Oil Service
= (LWB) Load Weighing Bypass
= (EAQ) Earthquake Service
= (EDT) Extended Door Time
= (EMP) Emergency Power Service
= (RSU) Reset Going Up
= (FS2) Fire Service Phase 2
= (RSD) Reset Going Dow
= (FSM) Fire Phase 1 Main Return
= (SEC) Security Recall
= (FSA) Fire Phase 1 Alt Return
= (TUG) TUG Service
= (EPR) Emergency Power Recall
= (SAB) Sabbath Service
= (HSV) Hospital Service
= (ATT) Attendant Service
= (MED) Medical Emergency Service
= (HOM) Homing
= (CBL) Code Blue
= (AUT) Automatic Service
Table 5-1: Elevator Procedure
1 = Reset Mode
12 = Safety String Open
2 = Inspection
13 = Elevator Off Line
3 = Motion Mode: Up Fast
14 = Elevator Parked
4 = Motion Mode: Up Transition
15 = Waiting At Floor
5 = Motion Mode: Leveling Up
16 = Doors Procedure
6 = Motion Mode: Down Fast
17 = Elevator Stalled (or Low Oil)
7 = Motion Mode: Down Transition
18 = Elevator Resetting Hydro Jack
8 = Motion Mode: Leveling Down
19 = Elevator on Low Oil Pressure mode
9 = Motion Mode: Emergency Stop
20 = Elevator is in Automatic Learn Hoistway
10 = Motion Mode: Not Used
21 = Elevator is in Emergency Power Recovery
11 = Motion Mode: Emergency Slowdown
22= Hot Oil Mode

Table of Contents