GALaxy eHydro Elevator Controller Section 5 – LCD Interface
5-4
Table 5-0: Elevator Service
= (HOT) Hot Oil Operation
= (TST) Test Mode Service
= (CEO) Car Sw Elevator Off
= (FFS) Fire Fighter's Stop Switch
= (HEO) Hall Sw Elevator Off
= (MRS) Machine Room Stop Switch
= (AFS) At Floor Shutdown
- (IND) Independent Service
= (VIP) Priority VIP Service
= (LWC) Calibrate Load Weigher
= (DPS) Door Protection Svc
= (JAK) Jack Reset Service
= (STA) Stalled Out Of Svc
= (OVL) Load Weigh Overload
= (LWB) Load Weighing Bypass
= (EAQ) Earthquake Service
= (EDT) Extended Door Time
= (EMP) Emergency Power Service
= (FS2) Fire Service Phase 2
= (FSM) Fire Phase 1 Main Return
= (FSA) Fire Phase 1 Alt Return
= (EPR) Emergency Power Recall
= (ATT) Attendant Service
= (MED) Medical Emergency Service
= (AUT) Automatic Service
Table 5-1: Elevator Procedure
4 = Motion Mode: Up Transition
5 = Motion Mode: Leveling Up
6 = Motion Mode: Down Fast
17 = Elevator Stalled (or Low Oil)
7 = Motion Mode: Down Transition
18 = Elevator Resetting Hydro Jack
8 = Motion Mode: Leveling Down
19 = Elevator on Low Oil Pressure mode
9 = Motion Mode: Emergency Stop
20 = Elevator is in Automatic Learn Hoistway
10 = Motion Mode: Not Used
21 = Elevator is in Emergency Power Recovery
11 = Motion Mode: Emergency Slowdown