47
The operator can select the Weekly or Daily record setup from Normal Record and Intensive Record
setup.
Thus, the DVR would record as daily or weekly on setup configuration of “Normal and Intensive record” setup
mode.
- Pre-Event Recording Time: When the DVR is not in continuous recording mode, this setting determines the
amount of footage to be recorded before an event occurs.
(motion detection, alarm input etc.)
- Post- Event Recording Time : When the DVR is not in continuous recording mode, this setting
determines the amount of footage that is to be recorded after an event
occurs. (motion detection, alarm input etc.)
- Panic Recording: Disable: Disables the Panic recording function
Manual: It works by pressing the Panic button from Remote controller or Front panel
Press the Panic button again to stop the panic recording.
Auto: After starting the panic recording, it would be stopped automatically if assigned
time is over.
- Panic Recording Time: It is related with “AUTO” option of Panic recording.
- Event Link: Select the sensor channel and user defined event for each channel.
Normal Record
Parameter
-Drag the time to setup with
mouse.
The setup is different for
each time range, also
according to different
color