13-10-615 Page 66
Every Year
1. Check the relief valve for proper operation. See Section 4.
2. Check shutdowns for proper operation.
MAINTENANCE SCHEDULE
Maintenance Action
As Indicated by
AutoSentry
Controller
Every 8
Hours
Every
125
Hours
Every
1000
Hours
Every
8000 *
Hours
Every
Year
Change Air Filter ................................................................
Change Oil Separator .......................................................
Check Reservoir Oil Level .................................................
Check for Proper Load/Unload...........................................
Check Discharge Pressure/Temp ......................................
Check Dirt Accumulation on Cooler ...................................
Change Oil Filter Element..................................................
Change Compressor Lubricant (AEON 9000SP) * ............
Check Relief Valve.............................................................
* See Oil Change Interval Chart, Figure 5-7, page 49, for specific lubricant life.