GE 60-960-95 - Quick Exit (partition 1: 0012, partition 2: 0022); Exit Extension (partition 1: 0013, partition 2: 0023); Auto Stay Arming (partition 1: 0014, partition 2: 0024)

GE 60-960-95
104 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Concord Ultra 28
Phone Number (cs phone 1: 0100, cs phone 2: 0110, cs phone
3: 0120)
Phones-CS Phone 1-3 (Default = none)
This setting is used for programming the central station receiver phone number.
Phone numbers can be 1 to 24 digits long, including pauses or * and # charac-
ters.
To enter pauses, press C.
To enter *, press and hold 7 for about two seconds.
To enter #, press and hold 9 for about two seconds.
Note
The
PHONE NUMBER menus are not accessible if a Dealer Code is programmed and the
Installer Code is used to enter installer programming mode. To access these menus
when a Dealer Code is programmed, you must enter installer programming mode
using the Dealer Code.
Call-waiting services should be disabled to prevent interrupting panel communication
to the central monitoring station. To program a dialing prefix that disables call-waiting,
see the Call Wait Cancel setting under the menu
PHONE OPTIONS—GLOBAL.
For UL 1635 listed installations, a phone number must be programmed.
¾To program a Central Station Phone
Number:
1. With the display showing PHONE NUM-
BER _ (or current number), enter the
desired phone number. The display
flashes the entered number.
2. Press # and the display shows the new
number.
¾
To delete a Central Station Phone Num-
ber:
1. With the display showing PHONE NUM-
BER
(current number), press D. The dis-
play shows
PHONE NUMBER _.
High Level Rpts (cs phone 1: 0101, cs phone 2: 0111, cs
phone 3: 0121)
Phones-CS Phone 1-3 (Defaults: CS
Phone 1 = on, CS Phone 2&3 = off)
When this setting is on, the following conditions report to the central station:
Fire, Police, Auxiliary, and Duress alarms
No Activity
Receiver Failure (or jam)
Tamper conditions, including Zone Tampers and System Tamper (40 incor-
rect key presses or touchpad supervisory)
Entering or exiting Sensor Test mode
Phone Test
Note
For UL 1635 listed installations, this feature must be set to on.
¾To turn High-Level Reports off or on:
1. With the display showing HIGH LEVEL
RPTS OFF/ON
(current setting), press 1
(off) or 2 (on). The display flashes the
entered setting.
2. Press # and the display shows the new
setting.
Low Level Rpts (cs phone 1: 0102, cs phone 2: 0112, cs phone
3: 0122)
Phones-CS Phone 1-3 (Defaults: CS
Phone 1 = on, CS Phone 2&3 = off)
When this setting is on, the following non-alarm conditions report to the central
station:
Force Armed
Hardwire Zone Trouble (open or short)
Supervisory (wireless devices)
Low Battery (wireless devices)
Phone Test
Other non-alarm related conditions
Note
For UL 1635 listed installations, this feature must be set to on.
¾To turn Low-Level Reports off or on:
1. With the display showing LOW LEVEL
RPTS OFF/ON
(current setting), press 1
(off) or 2 (on). The display flashes the
entered setting.
2. Press # and the display shows the new
setting.