Concord Ultra 36
Timers Menu
The TIMERS menu lets you set up the various system feature times that affect the whole system 
(global) or a specific partition.
The following describes how to program the timer settings that appear under 
GLOBAL.
Phone Access Key (partition 1: 0216, partition 2: 0226)
Phone Options-Partition 1-2 (Default = #)
This setting determines which touch-tone phone button is used for system 
access and control. 
If the Local Phone Control feature is enabled, the user can pick up the 
phone and press # (within 5 seconds) to access the security system. The 
panel seizes the phone line and waits for the user to enter system com-
mands. Phone access can be changed from # to * (see the following note).
Note  
Use the default setting (#) to avoid conflicts between the security system and 
other phone devices and services. Many phone devices (such as answering 
machines, computer modems, and FAX machines) and services (such as call-
waiting, call-forwarding, and some banking transactions) require * to initiate 
their operation, so using * for this security feature could cause conflicts.
¾To change the Phone Access Key:
1. With the desired partition selected, press A or 
B until the display shows 
PHONE ACCESS KEY 
#/* (current setting).
2. Press 1 (for *) or 2 (for #). The display flashes 
the entered setting. 
3. Press # and the display shows the new setting.
Supervisory Time (0300)
Timers-Global (Default = random between 01:00 and 04:00)
This setting determines what time of day the panel 
sends supervisory, low battery, or auto phone test 
reports to the central station. 
Note  
The panel clock must be set with the correct time for accu-
rate supervisory time reporting. See “Time and Date Menu”.
¾To set the Supervisory Time:
1. With the display showing SUPERVISORY TIME HH:MM (current 
setting), enter the desired 4-digit time value. For example, 
enter 0330 to set the supervisory time for 3:30 
A.M. The display 
flashes the entered setting. 
2. Press # and the display shows the new setting.
RF Tx Timeout (0301)
Timers-Global (Default = 12 hours)
This setting determines how many hours (2–24) the 
panel has to receive at least one signal from a wireless 
sensor (learned into a supervised group). If the panel 
does not receive a signal from any supervised wireless 
sensor within the set time, the panel reports a supervi-
sory condition to the central station.
Note  
For ULUL 985 & 1635 listed installations, the RF Tx Timeout 
must be set to 4 hours. For UL 1023 listed installations, the 
RF Tx Timeout must be set to 24 hours.
¾To set the RF Tx Timeout:
1. With the display showing RF TX TIMEOUT nn HOURS  (current 
setting), enter the desired timeout value (2–24). The display 
flashes the entered setting. 
2. Press # and the display shows the new setting.
Phone Test Freq. (0302)
Timers-Global (Default = 7 days)
This setting determines how often the panel conducts the auto-
matic phone test (see “Auto Phone Test” under 
PHONE 
OPTIONS—GLOBAL
). The system can be set to perform an auto-
matic phone test anywhere from every day to every 255 days.
Note  
For UL 1635 listed installations, this feature must be set to 1.
¾To set the Phone Test Freq:
1. With the display showing PHONE TEST FREQ nnn DAYS 
(current setting), enter the number of days (1–255). The 
display flashes the entered setting. 
2. Press # and the display shows the new setting.