Concord Ultra 38
Light Control Menu
Note  
For light control to work, X10 
Powerhouse Lamp Modules 
must be installed at desired 
lamps.
The LIGHT CONTROL menu lets you set up light activation for a specific partition.
The following describes how to program the light control settings that appear under 
PARTITION 1 
and 
PARTITION 2.
Extended Delay (partition 1: 0312, partition 2: 0322)
Timers-Partition 1-2 (Default = 4 min.)
This setting determines how much time the user has (after arming 
the system) to enter or exit the premises through a “designated 
extended delay door” (1–8 minutes).
Note  
For UL Listed installations Extended Delay may not be used.
¾To set the Extended Delay:
1. With the display showing EXTENDED DELAY n MIN-
UTES 
(current setting), enter the desired time value 
(1–8). The display flashes the entered setting. 
2. Press # and the display shows the new setting.
Siren Timeout (partition 1: 0313, partition 2: 
0323)
Timers-Partition 1-2 (Default = 4 min.)
This setting determines how long sirens sound (1–30 min-
utes) if no one is present to disarm the system. 
Note  
For UL Listed installations, the Siren Timeout must be set to 4 
minutes or more.
¾To set the Siren Timeout:
1. With the display showing SIREN TIMEOUT nn MINUTES (cur-
rent setting), enter the desired time value (1–30). The dis-
play flashes the entered setting. 
2. Press # and the display show the new setting.
Sleep Time (partition 1: 0314, partition 2: 0324)
Timers-Partition 1-2 (Default = 22:00 [10:00 pm])
This setting determines the start time of a 10 hour window 
during which trouble beeps are suppressed. The initial occur-
rence of an event that causes trouble beeps within this win-
dow will not sound trouble beeps until the Sleep Time 
window expires. If trouble beeps from a previous event are 
due to be restarted during the sleep time window, they will 
be restarted one hour prior to Sleep Time.
Note  
For UL listed installations, this feature must be set to off.
¾To set the Sleep Time:
1. With the display showing SLEEP TIME hh:mm (current set-
ting), enter the desired time value (00:00-23:50 using 10 
minute intervals). The display flashes the entered setting. 
2. Press # and the display show the new setting.
¾
To turn off Sleep Time:
1. With the display showing SLEEP TIME hh:mm (current set-
ting), press D.
Entry Lights (partition 1: 0400, partition 2: 
0410)
Light Control-Partition 1-2 (Default = none)
This setting determines which X10 controlled lights turn on 
during entry and exit delays.
Note  
X10 Lamp Modules set to 1 always turn on during the entry and 
exit delays. 
X10 Lamp Modules set to 2 always flash the arming level when 
arming the system. For example, lights flash two times when 
arming to STAY (level 2), and three times when arming to AWAY 
(level 3).
¾To set the Entry Lights:
1. With the desired partition selected, press #. The display 
shows ENTRY LIGHTS nnnnnnn (current setting).
2. Enter all the desired light numbers (3–9 based on the UNIT 
dial setting on each X10 Lamp Module). The display 
flashes the entered setting(s). 
3. Press # and the display shows the new setting(s).
¾
To delete Entry Lights:
1. Enter any light number that appears on the display, then 
press #. The number disappears from the display.