Table B1: Sensor Group Characteristics
No. Name Application Alarm Delay
Restoral
Supervisory
CS Report
Chime (Level 1)
Active Levels
00 Fixed Panic 24-hour audible fixed emergency buttons. Police Instant
1, 2, 3
01 Portable Panic 24-hour audible portable emergency buttons. Police Instant
1, 2, 3
02 Fixed Panic 24-hour silent fixed emergency buttons. Silent Instant
1, 2, 3
03 Portable Panic 24-hour silent portable emergency buttons. Silent Instant
1, 2, 3
04 Fixed Auxiliary
24-hour auxiliary sensor, such as Pendant Panic or
holdup button.
Auxiliary Instant
1, 2, 3
05 Fixed Auxiliary
24-hour auxiliary emergency button. Siren shutoff con-
firms CS report.
Auxiliary Instant
1, 2, 3
06 Portable Auxiliary 24-hour portable auxiliary alert button. Auxiliary Instant
1, 2, 3
07 Portable Auxiliary
24-hour portable auxiliary button. Siren shutoff con-
firms CS report.
Auxiliary Instant
1, 2, 3
08 Special Intrusion
Special belongings, such as gun cabinets and wall
safes.
Police Instant
1, 2, 3
09 Special Intrusion
Special belongings, such as gun cabinets and wall
safes.
Police Standard
1, 2, 3
10 Entry/Exit Delay
Entry and exit doors that require a standard delay
time.
Police Standard
2, 3
11 Entry/Exit Delay
Garage doors and entrances that require an extended
delay time. *
Police Extended
2, 3
12 Entry/Exit Delay
Driveway gates and entrances that require a twice
extended delay time. *
Police
Twice
Extended
2, 3
13 Instant Perimeter Exterior doors and windows. Police Instant
2, 3
14 Instant Interior Interior doors. Police Follower
2, 3
15 Instant Interior Interior PIR motion sensors. * Police Follower
2, 3
16 Instant Interior Interior doors. Police Follower
3
17 Instant Interior PIR motion sensors. * Police Follower
3
18 Instant Interior PIR motion sensors subject to false alarms. * Police Follower
3
19 Delayed Interior
Interior doors that initiate a delay before going into
alarm. *
Police Standard
3
20 Delayed Interior
PIR motion sensors that initiate a delay before going
into alarm. *
Police Standard
3
21
Local Instant
Interior
24-hour local alarm zone protecting anything that
opens and closes.
Police Instant
1, 2, 3
22
Local Delayed
Interior
Same as group 21, plus activation initiates a delay
before going into alarm.
Police Standard
1, 2, 3
23
Local Instant
Auxiliary
24-hour local alarm zone protecting anything that
opens and closes. ‡
Auxiliary Instant
1, 2, 3
24
Local Instant
Auxiliary
24-hour local alarm zone protecting anything that
opens and closes. Sirens shut off at restoral. *
Auxiliary Instant
1, 2, 3
25
Local Special
Chime
Notify the user when a door is opened. Sounds emit
from a local annunciator. *
Special
Chime
Instant
1, 2, 3