6.9.4 Connecting the Operating Mechanisms and Pole Columns
• Lubricate the shaft of pole B as per L2.
• Fit lever B (6) onto the shaft of pole B (2). 
• Apply locking adhesive S1 to the screw (9). Secure the lever with
the screw (9) and washer (10).
Tighten to a torque of 35 Nm.
• Insert the drive rod (5) into lever B (6).
• Turn lever B (6) in the direction of the arrow until the lever and the
shaft are in contact with one another. This reduces the clearance
between the lever and the shaft.
• Pull on the drive rod to reduce the clearance between the drive
shaft and operating lever.
• Check to make sure the holes in the lever and drive rod are
aligned. If required align the pole columns using a tire lever. (see
“Aligning the Pole Columns Using a Tire Lever (if required)”
on Page 44)
2Pole 1x
5 Drive rod 1x
6 Lever 1x
9 Hexagon screw, M10x25 A2-70 1x
10 Washer, 50.5/11/3 1x
11 Locking sleeve 1x
12 Washer, 6 A2 1x
13 Hexagon screw, M6x16 A2-70 1x
14 Flanged coupling pin, 16x68 1x
15 Sleeve 1x