RECONDITIONING
84 / 146 OI 250 (EN) REV7 /REV7
10.1.2 Removing the Double Motion System
• Remove eight screws (3) and washers (4) from the upper flange
of the chamber insulator (1).
• Carefully remove the double motion system (2).
1 Chamber insulator 1x
2 Double motion system 1x
3 Hexagon screw, M12x45 A2-70 8x
4 Washer, 12x40 A2 8x