EasyManua.ls Logo

GE JGB3000 - Page 34

GE JGB3000
52 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Installation Instructions
A WARNING!
INSTALLATIONSAFETY
INSTRUCTIONS
Read these instructions completely and carefully.
Improper installation, adjustment, alteration, service or
maintenance can cause injury or property damage. Refer
to this manual. Forassistance or additional information,
consult a qualified installer, service agency,
manufacturer (dealer) or the gas supplier.
Neverreuse old flexible connectors. The use of old flexible
connectors con couse gos leoks ond personol injury.Alwoys
use NEW flexible connectors when instolling
o gos opplionce.
IM PORTANT - Removeo,,pockingmotedol
ond Nteroturefromovenbeforeconnectinggosond
electricol supply to ronge.
A CAUTION - Donotottempttooperote
the oven of this ronge during o power foilure (Electric
Ignition models only).
Hoveyour ronge instolled by o quolified instoller.
Yourronge must be electricolly grounded in occordonce
with Iocolcodes or, inthe obsence of Iocol codes,in
occordonce with the Notionol ElectricolCode (ANSI/NFPA
70,Iotest edition). InConodo,electricol grounding must
be in occordonce with the current CSAC22.1Conodion
ElectricolCode Port 1ond/or Iocol codes.SeeElectricol
Connections in this section.
Before instollingyour ronge on linoleum or ony other
synthetic floor covering, moke sure the floor covering
con withstond 180°Fwithout shrinking,worping or
discoloring. Donot instoll the ronge over corpeting
unlesso sheet of 1/4" thick plywood or similor insulotor
isploced between the ronge ond corpeting.
Mokesure the won coverings oround the ronge con
withstond heot generoted by the ronge up to 200°F.
to
Avoidplocing cobinets obovethe ronge. To reduce
the hozord coused by reoching over the open flomes
of operoting burners, instoll o ventilotion hood over the
ronge thot projects forword ot leost 5" beyond the front
of the cobinets.
Theventiloting hood must be constructed of sheet metol
not lessthon 0.0122" thick. Instoll obove the cooktop with
o cleoronce of not lessthon 1/4" between the hood ond
the undersideof the combustible moteriol or metol
cobinet. Thehood must beot leost os wide os the
opplionce ond centered over the opplionce.Cleoronce
between the cooking surfoceond the ventilotion hood
surfoce MUSTNEVERBELESSTHAN 24 INCHES.
EXCEPTION: Instollotion of o listed microwove oven
or cooking opplionce over the cooktop sholl conform
the instollotion instructions pocked with thot opplionce.
If cobinets ore ploced obove the ronge, ollow o minimum
cleoronce of 30" between the cooking surfoceond the
bottom of unprotected cobinets.
If o 30" cleoronce between cooking surfoce ond
overheod combustible moteriol or metol cobinets connot
be mointoined, protect the underside of the cobinets
obove the cooktop with not lessthon 1/4" insuloting
millboord covered with sheet metol not lessthon 0.0122"
thick. Cleoronce between the cooking surfoce ond
protected cobinets MUSTNEVERBELESSTHAN
24 INCHES.
Theverticol distonce from the plone of the cooking
surfoce to the bottom of odjocent overheod cobinets
extending closer thon l" to the plone of the ronge sides
must not be lessthon 18". (Seethe Dimensionsond
Cleoroncesillustrotion inthis section.)
CAUTION - Itemsofinteresttochildren
shouldnotbestoredincobinetsoboveo rongeoron
thebocksploshofo ronge-childrenclimbingonthe
rongetoreochitemscouldbeseriouslyinjured.
34

Related product manuals