GE Multilin M60 Motor Protection System B-27
APPENDIX B B.4 MEMORY MAPPING
B
408B Port 1 Gateway IP Address 0 to 4294967295 --- 1 F003 56554497
408D Network Address NSAP --- --- --- F074 0
4097 Port 1 Link Loss Alert 0 to 1 --- 1 F102 0 (Disabled)
4098 Port 2 Link Loss Alert 0 to 1 --- 1 F102 0 (Disabled)
4099 Port 3 Link Loss Alert 0 to 1 --- 1 F102 0 (Disabled)
409A DNP Channel 1 Port 0 to 5 --- 1 F177 0 (None)
409B DNP Channel 2 Port 0 to 5 --- 1 F177 0 (None)
409C DNP Address 0 to 65519 --- 1 F001 1
409E DNP Client Addresses (2 items) 0 to 4294967295 --- 1 F003 0
40A3 TCP Port Number for the Modbus protocol 0 to 65535 --- 1 F001 502
40A4 TCP/UDP Port Number for the DNP Protocol 0 to 65535 --- 1 F001 20000
40A5 TCP Port Number for the HTTP (Web Server) Protocol 0 to 65535 --- 1 F001 80
40A6 Main UDP Port Number for the TFTP Protocol 0 to 65535 --- 1 F001 69
40A7 Data Transfer UDP Port Numbers for the TFTP Protocol
(zero means “automatic”) (2 items)
0 to 65535 --- 1 F001 0
40A9 DNP Unsolicited Responses Function 0 to 1 --- 1 F102 0 (Disabled)
40AA DNP Unsolicited Responses Timeout 0 to 60 s 1 F001 5
40AB DNP Unsolicited Responses Maximum Retries 1 to 255 --- 1 F001 10
40AC DNP Unsolicited Responses Destination Address 0 to 65519 --- 1 F001 1
40AD Ethernet Operation Mode 0 to 1 --- 1 F192 1 (Half-Duplex)
40AE DNP Current Scale Factor 0 to 8 --- 1 F194 2 (1)
40AF DNP Voltage Scale Factor 0 to 8 --- 1 F194 2 (1)
40B0 DNP Power Scale Factor 0 to 8 --- 1 F194 2 (1)
40B1 DNP Energy Scale Factor 0 to 8 --- 1 F194 2 (1)
40B2 DNP Power Scale Factor 0 to 8 --- 1 F194 2 (1)
40B3 DNP Other Scale Factor 0 to 8 --- 1 F194 2 (1)
40B4 DNP Current Default Deadband 0 to 100000000 --- 1 F003 30000
40B6 DNP Voltage Default Deadband 0 to 100000000 --- 1 F003 30000
40B8 DNP Power Default Deadband 0 to 100000000 --- 1 F003 30000
40BA DNP Energy Default Deadband 0 to 100000000 --- 1 F003 30000
40BC DNP Power Factor Default Deadband 0 to 100000000 -- 1 F003 30000
40BE DNP Other Default Deadband 0 to 100000000 --- 1 F003 30000
40C0 DNP IIN Time Synchronization Bit Period 1 to 10080 min 1 F001 1440
40C1 DNP Message Fragment Size 30 to 2048 --- 1 F001 240
40C2 DNP Client Address 3 0 to 4294967295 --- 1 F003 0
40C4 DNP Client Address 4 0 to 4294967295 --- 1 F003 0
40C6 DNP Client Address 5 0 to 4294967295 --- 1 F003 0
40C8 DNP Number of Paired Binary Output Control Points 0 to 32 --- 1 F001 0
40C9 DNP TCP Connection Timeout 10 to 65535 --- 1 F001 120
40CA DNP Communications Reserved (22 items) 0 to 1 --- 1 F001 0
40E0 TCP Port Number for the IEC 60870-5-104 Protocol 0 to 65535 --- 1 F001 2404
40E1 IEC 60870-5-104 Protocol Function 0 to 1 --- 1 F102 0 (Disabled)
40E2 IEC 60870-5-104 Protocol Common Address of ASDU 0 to 65535 --- 1 F001 0
40E3 IEC 60870-5-104 Protocol Cyclic data Transmit Period 1 to 65535 s 1 F001 60
40E4 IEC 60870-5-104 Current Default Threshold 0 to 100000000 --- 1 F003 30000
40E6 IEC 60870-5-104 Voltage Default Threshold 0 to 100000000 --- 1 F003 30000
40E8 IEC 60870-5-104 Power Default Threshold 0 to 100000000 --- 1 F003 30000
40EA IEC 60870-5-104 Energy Default Threshold 0 to 100000000 --- 1 F003 30000
40EC IEC 60870-5-104 Power Default Threshold 0 to1 --- 0.01 F001 100
40EE IEC 60870-5-104 Other Default Threshold 0 to 100000000 --- 1 F003 30000
40F0 IEC 60870-5-104 Client Address (5 items) 0 to 4294967295 --- 1 F003 0
4104 IEC 60870-5-104 Redundancy Port 0 to 1 --- 1 F126 0 (No)
4105 Port 2 IP Address 0 to 4294967295 --- 1 F003 56554706
4107 Port 2 IP Subnet Mask 0 to 4294967295 --- 1 F003 4294966272
Table B–9: MODBUS MEMORY MAP (Sheet 20 of 66)